PLANE77
2D 8-Node
Thermal Solid
PLANE77 Element Description
Although this element is available for use in your analysis, Ansys, Inc. recommends using a current-technology element such as PLANE293. |
PLANE77 is a higher order version of the 2D, 4-node thermal element (PLANE55). The element has one degree of freedom, temperature, at each node. The 8-node elements have compatible temperature shapes and are well suited to model curved boundaries.
The 8-node thermal element is applicable to a 2D, steady-state or transient thermal analysis. See PLANE77 in the Mechanical APDL Theory Reference for more details about this element. If the model containing this element is also to be analyzed structurally, the element should be replaced by an equivalent structural element (such as PLANE183). A similar axisymmetric thermal element which accepts nonaxisymmetric loading is PLANE78.
PLANE77 Input Data
The geometry, node locations, and the coordinate system for this element are shown in Figure 77.1: PLANE77 Geometry. The element is defined by eight nodes and orthotropic material properties. A triangular-shaped element may be formed by defining the same node number for nodes K, L and O.
Orthotropic material directions correspond to the element coordinate directions. The element coordinate system orientation is as described in Coordinate Systems. Specific heat and density are ignored for steady-state solutions. Properties not input default as described in the Material Reference.
Element loads are described in Element Loading. Convection or heat flux (but not both) and radiation may be input as surface loads at the element faces as shown by the circled numbers on Figure 77.1: PLANE77 Geometry. Heat generation rates may be input as element body loads at the nodes. If the node I heat generation rate HG(I) is input, and all others are unspecified, they default to HG(I). If all corner node heat generation rates are specified, each midside node heat generation rate defaults to the average heat generation rate of its adjacent corner nodes.
This element can also have a Z-depth specified by KEYOPT(3) and real constant THK. Be careful when using this option with other physics, especially radiation. Radiation view factors will be based on a unit Z-depth (only).
A summary of the element input is given in "PLANE77 Input Summary". A general description of element input is given in Element Input. For axisymmetric applications see Harmonic Axisymmetric Elements.
For phase change problems (refer to Phase Change in the Thermal Analysis Guide), use KEYOPT(1) = 1 (diagonalized specific heat matrix).
PLANE77 Input Summary
- Nodes
I, J, K, L, M, N, O, P
- Degrees of Freedom
TEMP
- Real Constants
THK = Thickness (used only if KEYOPT(3) = 3)
- Material Properties
MP command: KXX, KYY, DENS, C, ENTH
- Surface Loads
- Convection or Heat Flux (but not both) and Radiation (using Lab = RDSF) --
face 1 (J-I), face 2 (K-J), face 3 (L-K), face 4 (I-L)
- Body Loads
- Heat Generations --
HG(I), HG(J), HG(K), HG(L), HG(M), HG(N), HG(O), HG(P)
- Special Features
- KEYOPT(1)
Specific heat matrix:
- 0 --
Consistent specific heat matrix
- 1 --
Diagonalized specific heat matrix
- KEYOPT(3)
Element behavior:
- 0 --
Plane
- 1 --
Axisymmetric
- 3 --
Plane with Z-depth, specified via real constant THK.
PLANE77 Output Data
The solution output associated with the element is in two forms:
Nodal temperatures included in the overall nodal solution
Additional element output as shown in Table 77.1: PLANE77 Element Output Definitions
The element output directions are parallel to the element coordinate system. For an axisymmetric analysis the face area and the heat flow rate are on a full 360° basis. Convection heat flux is positive out of the element; applied heat flux is positive into the element. A general description of solution output is given in Solution Output. See the Basic Analysis Guide for ways to view results.
The Element Output Definitions table uses the following notation:
A colon (:) in the Name column indicates that the item can be accessed by the Component Name method (ETABLE, ESOL). The O column indicates the availability of the items in the file jobname.out. The R column indicates the availability of the items in the results file.
In either the O or R columns, “Y” indicates that the item is always available, a letter or number refers to a table footnote that describes when the item is conditionally available, and “-” indicates that the item is not available.
Table 77.1: PLANE77 Element Output Definitions
Name | Definition | O | R |
---|---|---|---|
EL | Element Number | Y | Y |
NODES | Nodes - I, J, K, L, M, N, O, P | Y | Y |
MAT | Material number | Y | Y |
VOLU: | Volume | Y | Y |
XC, YC | Location where results are reported | Y | 2 |
HGEN | Heat generations HG(I), HG(J), HG(K), HG(L), HG(M), HG(N), HG(O), HG(P) | Y | - |
TG:X, Y, SUM | Thermal gradient components and vector sum at centroid | Y | Y |
TF:X, Y, SUM | Thermal flux (heat flow rate/cross-sectional area) components and vector sum at centroid | Y | Y |
FACE | Face label | 1 | - |
NODES | Face nodes | 1 | - |
AREA | Face area | 1 | 1 |
HFILM | Film coefficient | 1 | - |
TAVG | Average face temperature | 1 | 1 |
TBULK | Fluid bulk temperature | 1 | - |
HEAT RATE | Heat flow rate across face by convection | 1 | 1 |
HEAT RATE/AREA | Heat flow rate per unit area across face by convection | 1 | - |
HFAVG | Average film coefficient of the face | - | 1 |
TBAVG | Average face bulk temperature | - | 1 |
HFLXAVG | Heat flow rate per unit area across face caused by input heat flux | - | 1 |
HFLUX | Heat flux at each node of face | 1 | - |
Available only at centroid as a *GET item.
Table 77.2: PLANE77 Item and Component Labels lists output available through the ETABLE command using the Sequence Number method. See The General Postprocessor (POST1) in the Basic Analysis Guide and The Item and Sequence Number Table in this reference for more information. The following notation is used in Table 77.2: PLANE77 Item and Component Labels:
- Name
output quantity as defined in the Table 77.1: PLANE77 Element Output Definitions
- Item
predetermined Item label for ETABLE command
- FCn
sequence number for solution items for element Face n
PLANE77 Assumptions and Restrictions
The area of the element must be positive.
The 2D element must lie in an X-Y plane as shown in Figure 77.1: PLANE77 Geometry and the Y-axis must be the axis of symmetry for axisymmetric analyses.
An axisymmetric structure should be modeled in the +X quadrants.
A face with a removed midside node implies that the temperature varies linearly, rather than parabolically, along that face. See Quadratic Elements (Midside Nodes) in the Modeling and Meshing Guide for more information about the use of midside nodes.
The specific heat and enthalpy are evaluated at each integration point to allow for abrupt changes (such as melting) within a coarse grid.
If the thermal element is to be replaced by a PLANE183 structural element with surface stresses requested, the thermal element may be oriented such that face IJ and/or face KL is a free surface. A free surface of the element (that is, not adjacent to another element and not subjected to a boundary constraint) is assumed to be adiabatic.
Thermal transients having a fine integration time step and a severe thermal gradient at the surface will require a fine mesh at the surface.
For phase change problems, use the lower order element PLANE55 if at all possible.
Plotting temperature in /POST1 is based on corner nodes only. To include midside nodes in the plot, issue /EFACET,2 before PLNSOL,TEMP.