This section describes how to deal with the following problems:
- 25.2.1. A Linearized Stress Result Cannot Be Solved.
- 25.2.2. A Load Transfer Error Has Occurred.
- 25.2.3. A Master Node is Missing from the Condensed Part
- 25.2.4. Although the Exported File Was Saved to Disk
- 25.2.5. Although the Solution Failed to Solve Completely at all Time Points.
- 25.2.6. An Error Occurred Inside the SOLVER Module: Invalid Material Properties
- 25.2.7. An Error Occurred While Solving Due To Insufficient Disk Space
- 25.2.8. An Error Occurred While Starting the Solver Module
- 25.2.9. An Internal Solution Magnitude Limit Was Exceeded.
- 25.2.10. An Iterative Solver Was Used for this Analysis
- 25.2.11. At Least One Body Has Been Found to Have Only 1 Element
- 25.2.12. At Least One Spring Exists with Incorrectly Defined Nonlinear Stiffness
- 25.2.13. Animation Does not Export Correctly
- 25.2.14. Application Not Closing as Expected
- 25.2.15. Assemblies Missing Parts
- 25.2.16. Cannot Undo Node Move
- 25.2.17. CATIA V5 and IGES Surface Bodies
- 25.2.18. Constraint Equations Were Not Properly Matched
- 25.2.19. Element n Located in Body (and maybe other elements) Has Become Highly Distorted
- 25.2.20. Error Inertia tensor is too large
- 25.2.21. Equivalent Creep Strain Ratio has Exceeded the Specified Limit Value
- 25.2.22. Failed to Load Microsoft Office Application
- 25.2.23. Illogical Reaction Results
- 25.2.24. Large Deformation Effects are Active
- 25.2.25. Missing fonts for the Docking Pane Buttons (Linux Platform Only)
- 25.2.26. MPC equations were not built for one or more contact regions or remote boundary conditions
- 25.2.27. One or More Contact Regions May Not Be In Initial Contact
- 25.2.28. One or more MPC or Lagrange Multiplier formulation based contact may have conflicts
- 25.2.29. One or More Parts May Be Underconstrained
- 25.2.30. One or More Remote Boundary Conditions is Scoped to a Large Number of Elements
- 25.2.31. Problems Unique to Background (Asynchronous) Solutions
- 25.2.32. Problems Using Solution
- 25.2.33. Proxy Server Environment Variable
- 25.2.34. Remote Points with Overlapping Geometry Selections are not Recommended within a Condensed Part
- 25.2.35. Running Norton AntiVirusTM Causes the Mechanical Application to Crash
- 25.2.36. The Correctly Licensed Product Will Not Run
- 25.2.37. The Deformation is Large Compared to the Model Bounding Box
- 25.2.38. The Initial Time Increment May Be Too Large for This Problem
- 25.2.39. The Joint Probe cannot Evaluate Results
- 25.2.40. The License Manager Server Is Down
- 25.2.41. Linux Platform - Localized Operating System
- 25.2.42. The Low/High Boundaries of Cyclic Symmetry
- 25.2.43. The Remote Boundary Condition object is defined on the Cyclic Axis of Symmetry
- 25.2.44. The Solution Combination Folder
- 25.2.45. The Solver Engine was Unable to Converge
- 25.2.46. The Solver Has Found Conflicting DOF Constraints
- 25.2.47. Problem with RSM-Mechanical Connection
- 25.2.48. Unable to Find Requested Modes
- 25.2.49. You Must Specify Joint Conditions to all Three Rotational DOFs
- 25.2.50. Fracture Meshing Problems
- 25.2.51. Lustre Parallel File Systems on Linux
- 25.2.52. An Error Occurred Inside the SOLVER Module