Figure 11.12: M-File property dialog
Parameter | Symbol | Description | Dimension (Range) |
1. Interface time step | N/A | This represents the communication time step between MATLAB/Simulink (master tool) and Motion. This field shows the default Motion value, but when performing co-simulation, the value set in the master tool is used. |
Time (Real > 0.0) |
2. M-file | N/A | This represents the name of the export file. | N/A |
3. S-Input List | N/A | This represents list of pre-defined S-Input. | N/A |
4. S-Output List | N/A | This represents list of pre-defined S-Output. | N/A |
5. Maximum step size factor | N/A |
You can change the level of the maximum step size before co-simulation using this parameter (see Figure 11.13: Maximum Step Size Factor below):
For more information, see Dynamic Parameters for Simulation Configuration. |
N/A (0.01 ≤ Real ≤ 1.0) |
6. Level of the solver message | N/A |
You can change the message level before co-simulation using this parameter, as follows: - No messages regarding co-simulation are written - Only co-simulation progress is recorded - All messages regarding co-simulation are written | N/A |
7. Export | N/A | This button performs the export file operation. | N/A |
If the value of the Maximum step size
factor is set to 1.0
, the Maximum step
size for Motion is equal to the Interface time
step.
If the value of the Maximum step size
factor is set to 0.1
, the Maximum step
size for Motion is equal to one tenth of the Interface time
step.