An Static Pressure load applies a constant pressure to one or more bodies in the acoustic fluid regions.
Note: If both Static Pressure and Temperature are defined, the ideal gas model is activated.
Analysis Types
The Static Pressure loading condition is available for Coupled Field Harmonic, Coupled Field Modal, Coupled Field Transient, Harmonic Acoustics, and Modal Acoustics analyses.
Common Characteristics
This section describes the characteristics of the boundary condition, including the application requirements, support limitations, and loading definitions and values.
Types Supported
3D Simulation: Supported.
2D Simulation: Not Supported.
Geometry Types: Geometry types supported for the Static Pressure boundary condition include:
Solid: Supported.
Surface/Shell: Not Supported.
Wire Body/Line Body/Beam: Not Supported.
Topology: The following topology selection options are supported for Static Pressure.
Body: Supported.
Face: Not Supported.
Edge: Not Supported.
Vertex: Not Supported.
Nodes: Not Supported.
Element: Not Supported.
Element Face: Not Supported.
Loading Types: This boundary condition’s loading is only applied to the volume of the selected topology.
Loading Data Definition: Loading data specified as a constant only.
Boundary Condition Application
To apply a Static Pressure:
On the Environment Context tab: click Acoustic Loads>Static Pressure. Or, right-click the Environment tree object or in the Geometry window and select Insert>Acoustics>Static Pressure.
Define the Scoping Method. Options include Geometry Selection (default) and Named Selection. For either scoping type, you must use the Body selection filter (on the Graphics Toolbar) for geometry selection or Named Selection definition. Only bodies specified in the acoustics Physics Region(s) can be selected or defined.
Define the Magnitude of the pressure.
Details View Properties
The selections available in the Details view are described below.
Category | Fields/Options/Description |
---|---|
Scope |
Scoping Method, options include:
|
Definition |
Type: Read-only field that describes the object - Static Pressure. : Enter a constant pressure value. Suppressed: Include ( - default) or exclude ( ) the boundary condition. |
Mechanical APDL References and Notes
Static Pressure is applied using the SPRE label of BF command. Also see the Non-Uniform Ideal Gas Material section in the Mechanical APDL Acoustic Analysis Guide for more information.
API Reference
See the Static Pressure section of the ACT API Reference Guide for specific scripting information.