/PBC
/PBC, Item
, --
, KEY
, MIN
, MAX
, ABS
Shows boundary condition (BC) symbols and values on displays.
Item
Label identifying the item:
U
—
Applied translational constraints (UX, UY, UZ).
ROT
—
Applied rotational constraints (ROTX, ROTY, ROTZ).
TEMP
—
Applied temperatures (TEMP, TBOT, TE2, TE3, . . ., TTOP).
PRES
—
Applied fluid pressures.
V
—
Applied flow velocities (VX, VY, VZ).
VOLT
—
Applied voltages.
MAG
—
Applied scalar magnetic potentials.
A
—
Applied vector magnetic potentials.
CONC
—
Concentration.
CHRG
—
Applied electric charge.
F or FORC
—
Applied structural forces (FX, FY, FZ).
M or MOME
—
Applied structural moments (MX, MY, MZ).
HEAT
—
Applied heat flows (HEAT, HBOT, HE2, HE3, . . ., HTOP).
FLOW
—
Applied fluid flow.
AMPS
—
Applied current flow.
FLUX
—
Applied magnetic flux.
CSG
—
Applied magnetic current segments.
RATE
—
Diffusion flow rate.
MAST
—
Master degrees of freedom.
CP
—
Coupled nodes.
CE
—
Nodes in constraint equations.
NFOR
—
POST1 nodal forces.
NMOM
—
POST1 nodal moments
RFOR
—
POST1 reaction forces.
RMOM
—
POST1 reaction moments (MX, MY, MZ).
PATH
—
Path geometry (undistorted) associated with the PATH command after a PDEF or PVECT command has been issued.
ACEL
—
Global acceleration (ACELX, ACELY, ACELZ vector).
OMEG
—
Global angular velocity (OMEGX, OMEGY, OMEGZ vector) and acceleration (DOMEGX, DOMEGY, DOMEGZ vector).
ALL
—
Represents all appropriate labels.
--
Unused field.
KEY
Symbol key:
0
—
Do not show symbol.
1
—
Show symbol.
2
—
Plot value next to symbol.
MIN
Minimum value in a range of values plotted on screen.
MAX
Maximum value in a range of values plotted on screen.
ABS
Absolute number. If
KEY
= 2 andABS
= 0, a number falling between theMIN
andMAX
is displayed. IfABS
is not specified, it defaults to 0. IfKEY
= 2 andABS
= 1, an absolute value falling between theMIN
andMAX
is displayed.ABS
= 1 lets you eliminate the display of numbers whose absolute values are less than a desired tolerance. For example, ifABS
= 1,MIN
= 10 andMAX
= 1e8, values such as .83646 and -5.59737 are not displayed.
Notes
The /PBC command adds degree of freedom constraint, force load, and other symbols to displays.
Symbols are applied to the selected nodes only. All arrow and
arrowhead symbols are oriented in the nodal coordinate system and
lie in two perpendicular planes. Force arrows are scaled proportional
to their magnitude. (If KEY
= 1, use /VSCALE to change arrow length.) For scalar quantities,
the specific component direction (that is, x, y, or z) of the symbol
has no meaning, but the positive or negative sense (for example, positive
or negative x) represents a positive or negative scalar value, respectively.
The effects of the /PBC command are not cumulative (that is, the command does not modify an existing setting from a previously issued /PBC command). If you issue multiple /PBC commands during an analysis, only the setting specified by the most recent /PBC command applies.
Use /PSTATUS or /PBC,STAT to display settings. Use /PBC,DEFA to reset all specifications back to default. See the /PSF and /PBF commands for other display symbols.
In a cyclic symmetry analysis, the /PBC command is deactivated when cyclic expansion is active (/CYCEXPAND,,ON). To view boundary conditions on the base sector, deactivate cyclic expansion (/CYCEXPAND,,OFF) and issue this command: /PBC,ALL,,1
Issuing the command /PBC,PATH, ,1 displays all defined paths.
The /PBC command is valid in any processor.