GRP
GRP, SIGNIF
,
Label
, --
,
ForceType
Specifies the grouping mode combination method.
SIGNIF
Combine only those modes whose significance level exceeds the
SIGNIF
threshold. For single-point, multi-point, or DDAM response spectrum (Spectype
= SPRS, MPRS, or DDAM on SPOPT), the significance level of a mode is defined as the mode coefficient divided by the maximum mode coefficient of all modes. Any mode whose significance level is less thanSIGNIF
is considered insignificant and is not contributed to the mode combinations. The higher theSIGNIF
threshold, the fewer the number of modes combined.SIGNIF
defaults to 0.001. IfSIGNIF
is specified as 0.0, it is taken as 0.0. (This mode combination method is not valid for SPOPT,PSD.)Label
Label identifying the combined mode solution output.
DISP
—
Displacement solution (default). Displacements, stresses, forces, etc., are available.
VELO
—
Velocity solution. Velocities, "stress velocities," "force velocities," etc., are available.
ACEL
—
Acceleration solution. Accelerations, "stress accelerations," "force accelerations," etc., are available.
--
Unused field.
ForceType
Label identifying the forces to be combined:
STATIC
—
Combine the modal static forces (default).
TOTAL
—
Combine the modal static plus inertial forces.
Notes
The SIGNIF
value set with this command
(including the default value of 0.001) overrides the SIGNIF
value set with the MXPAND command.