EKILL

EKILL, ELEM
Deactivates an element (for the birth and death capability).

Valid Products: Pro | Premium | Enterprise | PrepPost | Solver | AS add-on

ELEM

Element to be deactivated. If ALL, deactivate all selected elements (ESEL). If ELEM = P, graphical picking is enabled and all remaining command fields are ignored (valid only in the GUI). A component name may also be substituted for ELEM. To specify a table, enclose the table name in percent signs (%), e.g. EKILL,%tabname%.

Notes

Deactivates the specified element when the birth and death capability is being used. A deactivated element remains in the model but contributes a near-zero stiffness (or conductivity, etc.) value (ESTIF) to the overall matrix. Any solution-dependent state variables (such as stress, plastic strain, creep strain, etc.) are set to zero. Deactivated elements contribute nothing to the overall mass (or capacitance, etc.) matrix, and do not generate a load vector (pressures, convections, gravity, etc.).

The usage of tabular input is described in Using TABLE Type Array Parameters to Control Birth and Death in the Advanced Analysis Guide.

The element can be reactivated with the EALIVE command.

This command is also valid in PREP7.

Menu Paths

Main Menu>Preprocessor>Loads>Load Step Opts>Other>Birth & Death>Kill Elements
Main Menu>Solution>Load Step Opts>Other>Birth & Death>Kill Elements