*VPUT
*VPUT, ParR
, Entity
, ENTNUM
, Item1
, IT1NUM
, Item2
, IT2NUM
, KLOOP
Restores array parameter values into the Mechanical APDL database.
Argument Descriptions
ParR
The name of the input vector array parameter. See *SET for name restrictions. The parameter must exist as a dimensioned array (*DIM) with data input.
Entity
Entity keyword. Valid keywords are shown for
Entity
= in the table below.ENTNUM
The number of the entity (as shown for
ENTNUM
= in the table below).Item1
The name of a particular item for the given entity. Valid items are as shown in the
Item1
columns of the table below.IT1NUM
The number (or label) for the specified
Item1
(if any). ValidIT1NUM
values are as shown in theIT1NUM
columns of the table below. SomeItem1
labels do not require anIT1NUM
value.Item2
,IT2NUM
A second set of item labels and numbers to further qualify the item for which data is to be stored. Most items do not require this level of information.
KLOOP
Field to be looped on:
- 0 or 2 --
Loop on the
ENTNUM
field (default).- 3 --
Loop on the
Item1
field.- 4 --
Loop on the
IT1NUM
field. Successive items are as shown withIT1NUM
.- 5 --
Loop on the
Item2
field.- 6 --
Loop on the
IT2NUM
field. Successive items are as shown withIT2NUM
.
Notes
The *VPUT command is not supported for PowerGraphics displays. Inconsistent results may be obtained if this command is not used in /GRAPHICS, FULL.
Plot and print operations entered via the GUI (AVPRIN command. This means that the principal and equivalent values are recalculated. If you use *VPUT to put data back into the database, issue the plot commands from the command line to preserve your data.
) incorporate theThis operation is basically the inverse of the *VGET operation. Vector
items are put directly (without any coordinate system transformation) into the Mechanical APDL database.
Items can only replace existing items of the database and not create new items. Degree of freedom
results that are replaced in the database are available for all subsequent postprocessing
operations. Other results are changed temporarily and are available mainly for the immediately
following print and display operations. The vector specification *VCUM does
not apply to this command. The valid labels for the location fields
(Entity
, ENTNUM
,
Item1
, and IT1NUM
) are listed below.
Item2
and IT2NUM
are not currently used.
Not all items from the *VGET list are allowed on *VPUT, as
putting values into some locations could cause the database to be inconsistent.
This command is valid in any processor.
Table 245: *VPUT - POST1 Items
Entity =
NODE, ENTNUM = n
(node number) | ||
---|---|---|
Item1 | IT1NUM | Description |
Valid labels for nodal degree of freedom results are: | ||
U | X, Y, Z | X, Y, or Z structural displacement. |
ROT | X, Y, Z | X, Y, or Z structural rotation. |
TEMP | Temperature. For SHELL131 and SHELL132 elements with KEYOPT(3) = 0 or 1, use TBOT, TE2, TE3, . . ., TTOP instead of TEMP. Alternative get functions: TEMP(N), TBOT(N), TE2(N), etc. | |
PRES | Pressure. | |
VOLT | Electric potential. | |
MAG | Magnetic scalar potential. | |
V | X, Y, Z |
X, Y, or Z fluid velocity. X, Y, or Z nodal velocity in a transient structural analysis (analysis with ANTYPE,TRANS). |
A | X, Y, Z |
X, Y, or Z magnetic vector potential. X, Y, or Z nodal acceleration in a transient structural analysis (analysis with ANTYPE,TRANS). |
CONC | Concentration. | |
CURR | Current. | |
EMF | Electromotive force drop. | |
Valid labels for element nodal results are: | ||
Item1 | IT1NUM | Description |
S | X, Y, Z, XY, YZ, XZ | Component stress. |
" | 1, 2, 3 | Principal stress. |
" | INT, EQV | Stress intensity or equivalent stress. |
EPTO | X, Y, Z, XY, YZ, XZ | Component total strain (EPEL + EPPL + EPCR). |
" | 1,2,3 | Principal total strain. |
" | INT, EQV | Total strain intensity or total equivalent strain. |
EPEL | X, Y, Z, XY, YZ, XZ | Component elastic strain. |
" | 1, 2, 3 | Principal elastic strain. |
" | INT, EQV | Elastic strain intensity or elastic equivalent strain. |
EPPL | X, Y, Z, XY, YZ, XZ | Component plastic strain. |
" | 1,2,3 | Principal plastic strain. |
" | INT, EQV | Plastic strain intensity or plastic equivalent strain. |
EPCR | X, Y, Z, XY, YZ, XZ | Component creep strain. |
" | 1, 2, 3 | Principal creep strain. |
" | INT, EQV | Creep strain intensity or creep equivalent strain. |
EPTH | X, Y, Z, XY, YZ, XZ | Component thermal strain. |
" | 1, 2, 3 | Principal thermal strain. |
" | INT, EQV | Thermal strain intensity or thermal equivalent strain. |
EPSW | Swelling strain. | |
NL | SEPL | Equivalent stress (from stress-strain curve). |
" | SRAT | Stress state ratio. |
" | HPRES | Hydrostatic pressure. |
" | EPEQ | Accumulated equivalent plastic strain. |
" | CREQ | Accumulated equivalent creep strain. |
" | PSV | Plastic state variable. |
" | PLWK | Plastic work/volume. |
TG | X, Y, Z | Component thermal gradient. |
TF | X, Y, Z | Component thermal flux. |
PG | X, Y, Z | Component pressure gradient. |
EF | X, Y, Z | Component electric field. |
D | X, Y, Z | Component electric flux density. |
H | X, Y, Z | Component magnetic field intensity. |
B | X, Y, Z | Component magnetic flux density. |
FMAG | X, Y, Z | Component electromagnetic force. |
Entity = ELEM, ENTNUM = n (element
number) | ||
Valid labels for element results are: | ||
Item1 | IT1NUM | Description |
ETAB | Lab | Any user-defined element table label (ETABLE). |