Submitting Polyflow Jobs to Remote Solve Manager

Use the following steps to submit Polyflow jobs to Remote Solve Manager (RSM).


Note:  Polyflow has the following limitations when used with Remote Solve Manager:

  • Reconnect does not work after moving a project to another machine.

  • Only one copy of a saved project that is in the pending state can reconnect successfully.

  • You must manually save a project after a reconnect.

  • The RSM interrupt option performs an abort operation, not an interrupt.

  • Parallel design point submissions to batch queue clusters only run on the head node and with the number of cores allocated by the batch queue scheduler.


In the Solution Process pane:

  1. Configure your remote solution settings in Remote Solve Manager. For more information see RSM Configuration in the Remote Solve Manager User's Guide.

  2. In Workbench, right-click the Solution cell and select Properties.

  3. In the Solution Process settings, set the Update Option to Submit to Remote Solve Manager.

  4. Select a RSM Queue.

  5. Update the project.

    You can interrupt or abort an update by right-clicking the Solution cell. These options are available during foreground, background and RSM updates.