Verify the Application of Mechanical-Generated Temperatures

Ensure that the temperatures generated by Mechanical are the same as those consumed by Maxwell. To verify the application of temperatures, check System Coupling's Transcript and EnSight-formatted Results files, as described in the following sections:

Review Temperatures in the Transcript

Review the Weighted Average value recorded for the Temperature transfer in the final coupling iteration to verify that the temperatures sent by Mechanical match those received by Maxwell.

Figure 4: Temperatures reported in the Transcript at 20 [s]


+=============================================================================+
| COUPLING STEP = 20                        SIMULATION TIME = 2.00000E+04 [s] |
+=============================================================================+

+=============================================================================+
|                             COUPLING ITERATIONS                             |
+-----------------------------------------------------------------------------+
|                                     |      Source            Target         |
+-----------------------------------------------------------------------------+
|                           COUPLING ITERATION = 1                            |
+-----------------------------------------------------------------------------+
| Ansys Electronics Desktop           |                                       |
|   Interface: CouplingInterface 1    |                                       |
|     Temperature                     |             Converged                 |
|       RMS Change                    |     5.96E-04          1.34E-04        |
|       Weighted Average              |     5.42E+02          5.42E+02        |
+-----------------------------------------------------------------------------+


Visualize Temperature Results in EnSight

In EnSight, visualize the application of Mechanical-generated temperatures to Maxwell's electromagnetic analysis. Use the following variables:

  • Mechanical (nodes): Temperature__NS

  • Maxwell (elements): Temperature__ES

Figure 5: Source-side and target-side Temperatures at 20 [s]

Source-side and target-side Temperatures at 20 [s]