Ensure that the temperatures generated by Mechanical are the same as those consumed by Maxwell. To verify the application of temperatures, check System Coupling's Transcript and EnSight-formatted Results files, as described in the following sections:
Review the Weighted Average value recorded for the Temperature transfer in the final coupling iteration to verify that the temperatures sent by Mechanical match those received by Maxwell.
Figure 4: Temperatures reported in the Transcript at 20 [s]
+=============================================================================+ | COUPLING STEP = 20 SIMULATION TIME = 2.00000E+04 [s] | +=============================================================================+ +=============================================================================+ | COUPLING ITERATIONS | +-----------------------------------------------------------------------------+ | | Source Target | +-----------------------------------------------------------------------------+ | COUPLING ITERATION = 1 | +-----------------------------------------------------------------------------+ | Ansys Electronics Desktop | | | Interface: CouplingInterface 1 | | | Temperature | Converged | | RMS Change | 5.96E-04 1.34E-04 | | Weighted Average | 5.42E+02 5.42E+02 | +-----------------------------------------------------------------------------+
In EnSight, visualize the application of Mechanical-generated temperatures to Maxwell's electromagnetic analysis. Use the following variables:
Mechanical (nodes): Temperature__NS
Maxwell (elements): Temperature__ES