Integration nodes are able to process designs provided at a special input slot. All parameter and response entries are registered at the upper (parametric) system. Parameters are applied from the flow design to the integration node. Responses are the results of the integration node and applied to the flow design. Further inputs coming from the workflow can be registered as input slots. Output slots are returned to the workflow as well.
Slots
Each integration node has some common slots and special slots depending on the solver type.
Common slots are:
Slot Name | Slot Type | Data Type | Description | ||||
---|---|---|---|---|---|---|---|
In | Out | ||||||
enabled_state | x | Conditional Execution of node. | |||||
BaseDir | x | Base directory | |||||
Design | x | Design to be solved. | |||||
ErrorCode | x | Information about success or error state. | |||||
+ New Slot | x | Input slot can be added. | |||||
Success | x | Information, whether the node successfully ran. | |||||
Design | x | Solved design. | |||||
ErrorCode | x | Information about success or error state. | |||||
WorkingDir | x | Path of the current working directory. | |||||
+ New Slot | x | Output slot can be added. |