6.6.2. Size of Secondary Droplets

The size of the secondary droplets d is modeled using a Nukiyama-Tanasawa distribution:

(6–90)

The mean size dm is derived as

(6–91)

where D is the incident droplet diameter, ρ l is the liquid density, ρ g is the ambient gas density.