6.6.2. Size of Secondary Droplets
The size of the secondary droplets d is modeled
using a Nukiyama-Tanasawa distribution:
The mean size dm
is derived
as
where D is the incident droplet diameter,
ρ
l
is the liquid density, ρ
g is the
ambient gas density.