For electric potential field or Li-ion battery calculations, you can generate graphical plots or alphanumeric reports of the following items. These quantities are available in the variable selection drop-down lists that appear in postprocessing dialog boxes.
Electric potential field:
In the Properties... category:
Electric Conductivity
In the Potential... category:
Electric Potential
Electric Conductivity
Electric Current Magnitude
Joule Heat Source
X Current
Y Current
Z Current
dPotential/dx
dPotential/dy
dPotential/dz
Li-ion battery (in the Lithium... category):
Lithium Concentration
Magnitude of Lithium Mass Flux Vector
X Lithium Mass Flux
Y Lithium Mass Flux
Z Lithium Mass Flux
Electrolysis (in the Potential... category):
Electrolyte Potential
Over Potential (mixture only)
Transfer Current (mixture only)
Osmotic Drag (mixture only)
Water Phase Change (phases only)
Water Content (mixture only)
Capillary Pressure (mixture only)
For the electric potential field, you can generate vector plots of the electric current fields by selecting Electric Current in the Vectors of drop-down list in Vectors Dialog Box.
For the Li-ion battery model, you can generate vector plots of the lithium mass flux by selecting Lithium Mass Flux in the Vectors of drop-down list in Vectors Dialog Box.
See Field Function Definitions for the definitions of these quantities.