Specifying the Curve for a Fan

You can define a fan curve based on Velocity or Volume flow rate. Enter pairs of the velocity versus pressure rise (static pressure) or volume flow rate versus pressure rise (static pressure).

The table must contain more than two rows of values, otherwise it will be implemented as a constant pressure rise. You can modify the table as needed and export values from it.

For any fans you've defined (and after accepting the fan settings), enter the name of the fan and click Save to local library for use in other simulations. You can also Remove from local library any added user-defined fans.