If you have non-standard variable names in your profile file, they can still be
used in CFX-Pre. Such names must be typed in as an expression directly in CFX-Pre,
because they will not be picked up automatically. For example, your file may contain
the variable uvel
for velocity in the U direction. On the
Boundary Details tab, you could enter
<profile>.uvel(x,y,z)
(where
<profile>
is the name of your profile) to pick up your
uvel
values.