16.6. Analysis and Solution Controls

A linear static analysis is performed.

Output controlled (OUTRES,CINT) is used to write the SIFs, J-integral, and T-stress results to the results (.rst) file and output files.

The following postprocessing commands can be used to list and/or plot and list the results:

/POST1
PLCINT,FRONT,1,,,K1				! Plot KI results
PLCINT,FRONT,1,,,K2				! Plot KII results
PLCINT,FRONT,1,,,K3				! Plot KIII results
PLCINT,FRONT,2						! Plot J-integral results
PLCINT,FRONT,3,,,TSTR			! Plot T-Stress results

PRCINT,1,ALL,K1					! Print KI results
PRCINT,1,ALL,K2					! Print KII results
PRCINT,1,ALL,K3					! Print KIII results
PRCINT,2,ALL,JINT					! Print J-integral results
PRCINT,3,ALL,TSTR					! Print T-Stress