STEF

STEF, VALUE
Specifies Stefan-Boltzmann radiation constant.

Valid Products: Pro | Premium | Enterprise | PrepPost | Solver | AS add-on

VALUE

Stefan-Boltzmann constant (defaults to 0.119E-10 Btu/hr/in2/ °R4).

Command Default

0.119E-10 Btu/hr/in2/ °R4.

Notes

You can use this command in the general preprocessor (PREP7) and in the Solution processor to specify the Stefan-Boltzmann constant in analyses using the radiation matrix method or the radiosity solver to model radiation.

Menu Paths

Main Menu>Preprocessor>Loads>Define Loads>Apply>Thermal>Ambient Rad>On Areas
Main Menu>Preprocessor>Loads>Define Loads>Apply>Thermal>Ambient Rad>On Elements
Main Menu>Preprocessor>Loads>Define Loads>Apply>Thermal>Ambient Rad>On Lines
Main Menu>Preprocessor>Loads>Define Loads>Apply>Thermal>Ambient Rad>On Nodes
Main Menu>Preprocessor>Radiation Opts>Solution Opt
Main Menu>Radiation Opt>Matrix Method>Other Settings
Main Menu>Radiation Opt>Radiosity Meth>Solution Opt
Main Menu>Solution>Define Loads>Apply>Thermal>Ambient Rad>On Areas
Main Menu>Solution>Define Loads>Apply>Thermal>Ambient Rad>On Elements
Main Menu>Solution>Define Loads>Apply>Thermal>Ambient Rad>On Lines
Main Menu>Solution>Define Loads>Apply>Thermal>Ambient Rad>On Nodes
Main Menu>Solution>Radiation Opts>Solution Opt