SSLN
SSLN, FACT, SIZE
Selects and displays small lines in the model.
FACTFactor used to determine small lines.
FACTtimes the average line length in the model is used as the line length limit below which lines will be selected.SIZELine length limit for line selection. Lines that have a length less than or equal to
SIZEwill be selected. Used only ifFACTis blank.
Notes
SSLN invokes a predefined Mechanical APDL macro for selecting small lines in a
model. Lines that are smaller than or equal to the specified limit
(FACT or SIZE) are selected and line
numbers are displayed. This command macro is useful for detecting very small lines in a model
that may cause problems (that is, poorly shaped elements or a meshing failure) during meshing.
All lines that are not "small" will be unselected and can be reselected with the