RFORCE
RFORCE, NVAR
, NODE
, Item
, Comp
, Name
Specifies the total reaction force data to be stored.
NVAR
Arbitrary reference number assigned to this variable (2 to NV (NUMVAR)). Overwrites any existing results for this variable.
NODE
Node for which data are to be stored. If
NODE
= P, graphical picking is enabled (valid only in the GUI).Item
Label identifying the item. Valid item labels are shown in the table below. Some items also require a component label.
Comp
Component of the item (if required). Valid component labels are shown in the table below.
Name
Thirty-two character name identifying the item on printouts and displays. Defaults to an eight character label formed by concatenating the first four characters of the
Item
andComp
labels.
Notes
Defines the total reaction force data (static, damping, and inertial components) to be stored from single pass (ANTYPE,STATIC or TRANS) solutions or from the expansion pass of mode-superposition (ANTYPE,HARMIC or TRANS) solutions.
Table 227: RFORCE - Valid Item and Component Labels
Valid item and component labels for node results are: | ||
---|---|---|
Item | Comp | Description |
F | X,Y,Z | X, Y, or Z structural force |
M | X,Y,Z | X, Y, or Z structural moment |
HEAT[1] | Heat flow | |
FLOW | Fluid flow | |
AMPS | Current flow | |
FLUX | Magnetic flux | |
CSG | X,Y,Z | X, Y, or Z magnetic current segment component |
RATE | Diffusion flow rate | |
VLTG | Voltage drop | |
CURT | Current | |
CHRG | Charge |