OCZONE
OCZONE, ZoneType
, ZoneName
, CompNameInt
, CompNameExt
Specifies the type of ocean zone data to follow.
ZoneType
The type of ocean zone data to be input following this command:
COMP
—
Define by a component.
ZLOC
—
Define by Z levels.
PIP
—
Associate an internal pipe or pipes with an external pipe.
ZoneName
The ocean zone name. If no name is specified, the program assigns one.
CompNameInt
For
Zonetype
= COMP, the required name of a component.For
Zonetype
= PIP, the required name of an internal pipe component.CompNameExt
For
Zonetype
= PIP, the required name of an external pipe component.
Notes
The OCZONE command specifies the type of ocean zone data to follow (component, Z-level, or internal pipes associated with an external pipe). An ocean zone is a local space where you can override global ocean-loading parameters.
Names specified for ZoneName
, CompNameInt
, and CompNameExt
can consist of up to 32 alphanumeric characters. The name cannot
contain punctuation, special characters, or spaces.
For Zonetype
= COMP, the zone is
defined by a component. Only the elements in the component are affected
by the local parameters. A partial component can be defined as the zone via the Z input on the OCTABLE command.
For Zonetype
= ZLOC, the zone is
defined by Z levels. Structural elements (such as BEAM188, BEAM189, PIPE288, PIPE289, and LINK180) in the Z levels are included in the zone.
For Zonetype
= PIP, the zone is prepared
for a special configuration of pipes. It associates an internal pipe
or pipes with an external pipe to remove the hydrodynamic effect on
the internal pipe. Only hydrostatic pressure is applied on the internal
pipe.
This command is also valid in PREP7.
Issue this command before defining your ocean load data (OCDATA or OCTABLE). Define components before defining a component-type or a pipe-type zone (OCZONE,COMP or OCZONE,PIP, respectively).