A transient analysis of 63.0x106 second duration is performed to simulate the two-year service life of the electrical component. The initial time step is 3.0x106 seconds. An initial normalized concentration of 1.0 and an initial temperature of 50°C are specified.
Geometric nonlinearity is activated (NLGEOM,ON), primarily to make hydrostatic pressure available during postprocessing. Loads are step-applied.


Some settings are implemented through the following command snippet:
! Initial Conditions ic,all,conc,1 ! initial normalized concentration kbc,1 ! step apply loads outres,all,all ! save all results TIMINT,ON,all tintp,,0.25251,0.50500,0.50000