17.6.7.1. Supported Analysis Types and Systems

The following table lists the systems that interact with one another using data transfer. The associated imported boundary conditions (as a data type) are show in parenthesis.

Source Analysis/System (Transfer Data Type)Target Analysis
CFD (Convection)Steady-State Thermal, Transient Thermal, Thermal-Electric
CFD (Pressure)Static Structural, Transient Structural [a] 1
CFD (Temperature)Steady-State Thermal, Transient Thermal, Thermal-Electric, Static Structural, Transient Structural[a]
CFD (Body Temperature)Static Structural, Transient Structural, LS-DYNA
Coupled Field Harmonic (Joule Heat)Steady-State Thermal and Transient Thermal
Coupled Field Harmonic (Velocity)Stand-alone Acoustics Coupled Field Harmonic
Coupled Field Static and Coupled Field Transient (Temperature)Static Structural and Transient Structural
Electric (Joule Heat)Steady-State Thermal, Transient Thermal
Electromagnetic (Force Density)Static Structural, Transient Structural[a]
Electromagnetic (Power Loss Density)Steady-State Thermal, Transient Thermal
Electromagnetic (Force and Moment)Harmonic Response[b]
External Files (Force, Temperature, Stress, Strain, Body Force Density)Static Structural, Transient Structural[a]
External Files (Displacement)Static Structural, Transient Structural[a], LS-DYNA
External Files (Temperature, Convection, Heat Flux, Heat Generation)Steady-State Thermal, Transient Thermal, Thermal-Electric
External Files (Pressure)Harmonic Response, Explicit Dynamics, LS-DYNA, Static Structural, Transient Structural[a], and Substructure Generation
External Files (Velocity)Acoustic Analysis
External Files - H5DPF file format (Velocity)Coupled Field Harmonic, Harmonic Acoustics
External Files (Imported Heat Flux, Imported Temperature, Imported (Thermal Condition) Body Temperature)Coupled Field Static, Coupled Field Transient
External Files (Imported Body Force Density)Harmonic Response
Harmonic Acoustics (Velocity)Harmonic Acoustics
Harmonic Response (Velocity)Harmonic Acoustic, LS-DYNA Acoustics Analysis
MotionHarmonic Acoustic Analysis, Coupled Field Harmonic
Polyflow (Temperature)Steady-State Thermal, Transient Thermal, Thermal-Electric, Static Structural, Transient Structural[a]
Static Structural, Transient Structural (Displacement, Temperature, Force[c], and Moment[c])Static Structural, Transient Structural[a]
Steady-State Thermal, Transient Thermal (Temperature)Static Structural, Transient Structural[a], Electric
System Coupling (Force)Static Structural, Transient Structural
System Coupling (Heat Flow, Convection, Temperature)Steady-State Thermal, Transient Thermal, Thermal-Electric
Thermal-Electric (Temperature)Static Structural, Transient Structural[a]

[a] Rigid dynamics solver is not supported.

[b] See the Importing Data into a Harmonic Analysis section for the specific steps to perform the analysis.

[c] Supported for Beam to Shell or Solid Submodeling only