Review the Sum value recorded for the final coupling iteration to verify that the losses sent by Maxwell match those received by Fluent.
Figure 32: Losses reported in the Transcript at Coupling Step 1, Iteration 4
+=============================================================================+ | COUPLING STEP = 1 | +=============================================================================+ +=============================================================================+ | COUPLING ITERATIONS | +-----------------------------------------------------------------------------+ | | Source Target | +-----------------------------------------------------------------------------+ ... +-----------------------------------------------------------------------------+ | COUPLING ITERATION = 4 | +-----------------------------------------------------------------------------+ ... +-----------------------------------------------------------------------------+ | Fluid Flow (Fluent) | | | Interface: Rotor | | | Rotor Losses | Converged | | RMS Change | 3.50E-09 9.53E-10 | | Sum | 5.13E+00 5.13E+00 | | Interface: Stator | | | Stator Losses | Converged | | RMS Change | 9.15E-09 7.12E-09 | | Sum | 8.20E+01 8.20E+01 | | Interface: Magnets | | | Magnet Losses | Converged | | RMS Change | 1.00E-14 1.00E-14 | | Sum | 7.20E-01 7.20E-01 | +-----------------------------------------------------------------------------+