31.2.6. AMF Direct Solver + Secant + ILU

It is possible to combine the previously described secant strategy with the ILU solver and to take advantage of both approaches. This approach is know to work in more than 90% of the Ansys Polyflow problems, but saving on the CPU/memory cannot be guaranteed. In order to consider this option, both secant and ILU strategies should be of interest individually.