The SimulationX integration allows you to use SimulationX files (*.ism, *.isx) as solver within an optiSLang workflow. Use the file selector to open a file, the parameters and results then appear in the editor window.
Define Parameters
All existing parameters can be used as optiSLang parameters. Optionally, lower and upper bounds can be defined directly in SimulationX using a parameters min and max attribute.
Define results
All results with activated protocol can be used as optiSLang responses. You can select:
Scalar MinValue
Scalar MaxValue
Scalar MeanValue
Scalar LastValue
Signal ProtValues
Node Settings
This node provides the following settings:
Name | Default value | Description |
---|---|---|
general.Version | 3.9 | Defines the SimulationX version called from optiSLang. |
general.Save isx / ism | False | Saves updated model in the design directory. |
general.Save log messages | False | Saves log messages in the design directory. |
general.Show GUI | True | Show or hide the SimulationX user interface during computation. |
general.Freeze GUI | False | Freeze the SimulationX user interface during computation. |
general.Maximum runtime | 0.0 | Sets the maximum runtime in seconds before terminating the computation process. (0.0=infinite) |
Run Options
This node has general Run Options. The number of supported options is individual for each node.
Supported Versions
See the Supported Integration Versions table.