The equations shown in the last section can be resolved and equivalent results can be calculated by Rocky considering the same input data and boundary conditions. The input parameters for this verification case setup are presented in Table 2.9: Verification case input parameters..
Table 2.9: Verification case input parameters.
|
Parameter |
Value |
Unit |
|---|---|---|
|
Physical Model: | ||
| Thermal | Disabled | - |
| Normal Force | Linear Spring Dashpot | - |
| Adhesive Force | None | - |
| Restitution Coefficient | Varied | - |
| Gravity Y | -9.81 | |
|
Sphere: | ||
| Sphere Radius | 0.2 | |
| Sphere Density | 2,600 | |
| Friction Coefficient | 0 | - |
| Young Modulus | 200,000 | Pa |
|
Plate: | ||
| X and Z dimensions | 1 | |
| Young Modulus | 200,000 | Pa |
|
Solver Parameters: | ||
| Simulation Duration | 0.5 | |