The Profile Transformation
pitch-change method:
Is available when there is at least one interface that uses the
Transient Rotor Stator
frame change/mixing model.Applies to any domain interface using the
Transient Rotor Stator
frame change/mixing model that is not used in the Time Transformation or Fourier Transformation model.Uses conventional periodicity at periodic boundaries (that is, has no special time lag for phase shift treatment).
When using the Transient Method > Option of
Time Integration
, results in the same solution as a transient simulation that uses theTransient Rotor Stator
frame change/mixing model with the same time step specifications.
Note: See Profile Transformation in the CFX-Solver Theory Guide for more theoretical information about the Profile Transformation method.