Information on radiation modeling in solid/multiple domains is available in Domain Considerations.
Optional parameter to indicate the total number of histories to be tracked for the simulation. The default value is 10000. This can have a large effect on the accuracy of simulation results. For details, see Monte Carlo Statistics. For information on interpreting Monte Carlo results, see Monte Carlo Model.
The Transfer Mode setting defines which radiative
transfer mode is enabled. The default value is Participating
Media
(that is, the domain material emits, absorbs, and/or
scatters radiation). The Surface to Surface
option implies
that volumetric emission, absorption and scattering are ignored regardless of
the specified material properties.
Note: Solution time may be adversely affected when using the Surface to Surface
option in a case involving a subdomain that
only partially covers the whole domain. With the Surface to Surface
option, the CFX-Solver
tries to reduce the radiation mesh to a single element (because only surfaces are of interest) but the presence of the subdomain
causes the number of elements to be at least two, triggering a potentially time-consuming ray trace.
This problem applies to both the Discrete Transfer and Monte Carlo models.
The workaround is to use the Participating Media
option instead of the
Surface to Surface
option and adjust the coarsening controls to produce a coarser radiation
mesh than the default. Choosing a coarsening rate that produces a few hundred radiation elements should
result in a solution similar to that under the Surface to Surface
option,
but with perhaps not the same resolution of the intensity field at the boundaries.
See Spectral Model.
See Scattering Model.