VMR031-T1
VMR031-T1
Laminated Strip under Three-Point Bending
Test Description
A 7-layered symmetric strip of length 50mm, width 10mm, and thickness 1mm is simply supported from either end at a distance of 10mm, and is loaded by a central line load of 10N/mm.
Material Properties | Geometric Properties | Lay up | Boundary conditions and loading | |||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
|
| [0/90/0/90/0/90/0] Thickness of central ply is four times as thick as others | Simply supported at x=10mm and x=45mm Symmetry is approximately =25mm and y=5mm Line load of 10N/mm at x=25mm and z=1mm |