9.2. Problem Description

A COPV is subjected to a uniform internal pressure and a temperature field with a constant through-the-wall gradient.

A nonlinear static analysis is performed to obtain stress and strain results of all layers under large-deformation conditions.

Failure criteria (FC) analysis and stress linearization are conducted based on the simulation results.