When performing an inverse-solving analysis, consider the following:
If you observe a significant difference in loop test results, try using tighter convergence criteria and an equal number of substeps to obtain matching results.
If you apply displacement-type loading during the inverse-solving analysis, apply it with the reverse sign. For more information, see Applying Loads in an Inverse-Solving Analysis in the Structural Analysis Guide.