RIGRESP
RIGRESP, Option, Method, Val1, Val2
Specifies the rigid response calculation.
OptionFlag to activate or deactivate the rigid response calculation:
1 (ON or YES)
—
Activate.
2 (OFF or NO)
—
Deactivate. This value is the default.
MethodMethod used to calculate the rigid response:
GUPTA
—
Gupta method.
LINDLEY
—
Lindley-Yow method.
Val1If
Method= GUPTA,Val1represents the frequency F1 in Hertz.If
Method= LINDLEY,Val1is the Zero Period Acceleration (ZPA). If a scale factor is defined (FACT in the SVTYP command), it is used to scale this valueVal2If
Method= GUPTA,Val2represents the frequency F2 in Hertz.
Notes
This rigid response calculation is only valid for single-point response spectrum analysis (SPOPT, SPRS) and multiple-point response spectrum analysis (SPOPT, MPRS) with combination methods square root of sum of squares (SRSS), complete quadratic (CQC) or Rosenblueth (ROSE).
This command is also valid in PREP7.