MAP
MAP, --, kDIM, --, kOUT, LIMIT
Maps pressures from source points to target surface elements.
--Unused field.
kDIMInterpolation key:
0 or 2
—
Interpolation is done on a surface (default).
3
—
Interpolation is done within a volume. This option is useful if the supplied source data is volumetric field data rather than surface data.
--Unused field.
kOUTKey to control how pressure is applied when a target node is outside of the source region:
0
—
Use the pressure(s) of the nearest source point for target nodes outside of the region (default).
1
—
Set pressures outside of the region to zero.
LIMITNumber of nearby points considered for interpolation. The minimum is 5; the default is 20. Lower values reduce processing time. However, some distorted or irregular meshes will require a higher
LIMITvalue to find the points encompassing the target node in order to define the region for interpolation.