ASIFILE

ASIFILE, Opt, Fname, Ext, Oper, kDim, kOut, LIMIT, --, ResOpt
Writes or reads one-way acoustic-structural coupling data.

Valid Products: Pro | Premium | Enterprise | PrepPost | Solver | AS add-on

Opt

Command behavior option:

WRITE

 — 

Write the structural results to the specified file.

READ

 — 

Read the structural results from the specified file. This option is invalid during /POST1 postprocessing.

Fname

File name and directory path of a one-way acoustic-structural coupling data file (248 characters maximum, including the characters needed for the directory path). An unspecified directory path defaults to the working directory; in this case, you can use all 248 characters for the file name (defaults to jobname).

Ext

File name extension of the one-way acoustic-structural coupling data file (defaults to .asi).

Oper

Command operation:

NOMAP

 — 

No mapping occurs between the structural and acoustic models when reading the structural results from the specified file (default).

MAP

 — 

Maps the results from the structural to the acoustic model. (See "Notes".)

kDim

Interpolation criteria. Valid only when Oper = MAP.

If kDim = 2 or 0, two-dimensional interpolation is applied (that is, interpolate occurs on a surface).

kOut

Outside region results. Valid only when Oper = MAP.

If kOut = 0, use the value(s) of the nearest region point for points outside of the region.

If kOut = 1, set results extrapolated outside of the region to zero.

LIMIT

Number of nearby nodes considered for interpolation. Valid only when Oper = MAP.

Minimum = 5. Default = 20.

Lower values reduce processing time; however, some distorted or irregular meshes require a higher value to encounter three nodes for triangulation.

--

Unused field.

ResOpt

Transient results option:

ACEL

 — 

Output or input the particle acceleration in a transient analysis (default).

VELO

 — 

Output or input the particle velocity in a transient analysis.

Notes

The ASIFILE command writes to, or reads from, a file containing one-way acoustic-structural coupling data.

Results data on the one-way coupling interface (defined by the SF,,FSIN command) in the structural model are written to the one-way coupling result data file during the structural solution.

By default, one-way coupling results data are read into the acoustic model as the velocity (harmonic) or acceleration (transient) excitation during the sequential acoustic solution. If the transient is to be solved with the velocity potential formulation in acoustics, set ResOpt = VELO to write/read the results data as velocity excitation.

If Oper = NOMAP, both structural and acoustic models must share the same node number on the one-way coupling interface.

If Oper = MAP:

  • The one-way coupling interface must be defined in the acoustic model (SF,,FSIN) such that it corresponds to the field-surface interface number (FSIN) in the structural model.

  • The output points are correct only if they are within the boundaries set via the specified input points.

  • Calculations for out-of-bound points require much more processing time than do points that are within bounds.

  • For each point in the acoustic destination mesh, the command searches all possible triangles in the structural source mesh to find the best triangle containing each point, then performs a linear interpolation inside this triangle. For faster and more accurate results, consider your interpolation method and search criteria carefully (see LIMIT).

You can also write an .asi file during postprocessing of the structural model. In the POST1 postprocessor (/POST1), issue the command ASIFILE,WRITE,Fname,Ext to output results on selected surface nodes of the structural model. In the subsequent acoustic analysis, apply the SF,,FSIN,1 command on the selected nodes of the acoustic model, and issue the ASIFILE,READ,Fname,Ext command to read the .asi file.

One-way coupling excitation can be applied to multiple frequencies or time steps.

Menu Paths