5.3.8. Failure Criteria vs. Ply Type Table

The table below illustrates which failure criteria evaluates the safety of the different ply types.

Failure CriteriaPly Type
Regular (UD)WovenHomogeneous CoreHoneycomb CoreIsotropicAdhesiveSandwich
Max Strain     
Max Stress     
Tsai-Wu     
Tsai-Hill     
Hofmann     
Hashin      
Puck√ [1]     
Cuntze      
LaRC      
Wrinkling      √ [2]
Core Failure     
Von Mises      
Shear Crimping     
Shear Stress     √ [3] 
Peel Stress     √ [3] 
  1. In combination with Puck for Woven specifications. See the section Puck for Woven.

  2. Sandwich is a laminate with at least one core layer.

  3. Only available if the add-on "Adhesive Failure Criteria" is enabled in ACP.