Postprocessed Quantities
Both preprocessing and postprocessing quantities are available when creating reports.
For example, when you create a Magnetostatic Report for the Magnetostatic Solver the following are four of the quantities that appear in the Category list in the Report dialog box:
- L – The postprocessed value of inductance (for example, the inductance of a 1-turn coil).
- Lnom – The inductance quantity that is solved with no post processing.
- MagFlux – The postprocessed value of the total magnetic flux as seen by the coil (current source) including all sources (current, magnets, etc.).
- MagFluxNom – The total magnetic flux quantity that is solved with no postprocessing as seen by the coil (current source) including all sources (current, magnets, etc.)
Similarly, for an Eddy Current Report, the following are three of the quantities that appear in the Category list:
- Winding – If the design includes windings, Flux Linkage, Induced Voltage, Input Current, Input Voltage, and Current quantities are available (depending on the winding type). See also Viewing Winding Results (Eddy Current).
- Loss – Hysteresis Loss (Maxwell 2D Eddy current solutions only), Core Loss, Solid Loss, Stranded Loss Stranded Loss R, and Stranded Loss AC. See also Viewing Loss Results (Eddy Current).
- End Connection (Maxwell 2D Eddy current solutions only) – Induced Voltage, and Current. See also Viewing End Connection Results (2D Eddy Current).