Target Residual for Transient Analysis Duration
The residual is defined to be the ratio of the global RMS value of the electric field at time t to the maximum RMS value in the time range zero to time t:
|
|
|
(1) |
|
|
|
(2) |
where
is the electric field at the ith interpolation point in the mesh
which contains a total of N interpolation
points. Note that the number of interpolation points is typically much
larger than the number of mesh vertices. The time duration of a simulation
can be controlled by specifying a target residual in db20 located in
the Duration tab of the solution setup.