Table 3.7: SPECIFY THE THERMOCOUPLE LOCATIONS Keyword Phrases
Keyword Phrase |
Description |
---|---|
SPECIFY THE THERMOCOUPLE LOCATIONS |
Title of keyword block used to specify the axial locations of thermocouple probes placed between the two quartz tubes. A series of up to 5 thermocouple locations are specified by giving the axial location and corresponding temperature. Thermocouple numbers must be specified in order of increasing |
Z(#) = |
Provides the axial location of the specified (# ≤ 5) thermocouple
relative to the beginning of the quartz tubes. Thermocouple numbers must be
specified in order of increasing Example: Z(1) = 8.73Z(2) = 20.8 Units: cm |