Material Models with Nonlinear Behavior (No Unit Conversion)

Material models which have nonlinear behavior do not allow for conversion of data from one unit system to another. For these material models, specify the units of the data in the Reference Units drop-down list. In Mechanical if an attempt is made to solve the solution, in a unit system which is not compatible with the Reference Units, an error is shown and the solution is stopped. The following material models have this restriction:

These material models require temperature values to be in an absolute scale. Mechanical writes all temperature inputs for a solver in °C or °F and includes a TOFFST command with the value appropriate to the solver unit system setting. This setting allows the computation of these material models to be performed correctly.