Clearing Generated Data

Clearing generated data removes or erases any data that the cell has generated, or is prepared to generate and store, if any such data is present. This data includes mesh, input files, solver files, and cached solution data. This operation may alter the state of the current cell and cells downstream from the selected cell.


Important:  For some systems, this operation results in specific behavior depending on the selected cell and in some cases specific system data (such as existing links). Refer to the following table for specific actions.


CellDataBehavior Description
Mechanical systems
Model Deletes mesh, input files, and solver files. Cleans results.
Setup Deletes input and solver files. Cleans results.
Solution Deletes solver files. Cleans results. Input files (such as ds.dat, CARep.xml) are left intact.
Results Cleans any solved results. Solver files are left intact.
SetupImported Temperature: One-way FSI inputCleans imported load and deletes transfer xml file. User specifications (such as scoping) are intact.
SetupImported Temperature: Thermal stressCleans imported load and deletes transfer xml file. User specifications (such as scoping) are intact.
ModelLink to CFXDeletes SYS.cmdb.
ModelLink to Mechanical APDLDeletes SYS.cdb.
SetupLink to Mechanical APDLNo additional action required (ds.dat is the natural output from the Setup cell).
SolutionLink to Mechanical APDLNo additional action required (file.rst is the natural output from the Solution cell).
Mechanical APDL
Analysis Deletes Ansys-generated files (created during Update or Edit). Files added using input links or Add xxx File are left intact.
Fluent
SolutionInternal, link to initialization dataCloses the session without saving data. Deletes all files currently associated with the cell (latest available solution data). Any schematic input links remain intact.

To clear generated data:

  1. Right-click the cell to clear and select Clear Generated Data from the context menu.