8.7.3. User Inputs for the Outflow Condition

To define an outflow condition on a boundary section, follow these steps:

  1. Select the Outflow menu item in the list of boundary condition choices.

      Outflow

    (For a generalized Newtonian flow, no further inputs are required.)

  2. For a viscoelastic flow, enter the value of flow rate, when prompted.

  3. Select the type of flow rate: volumetric flow rate or mass flow rate.

    The default type is Volumetric flow rate.

      Volumetric flow rate


    Note:  If you select Mass flow rate, you must define a positive and constant density.