Shrinkwrap Options

Num. of smooth iterations

is the number of smoothing iterations that will be performed to improve mesh quality.

Surface projection factor

controls the tightness of the shrinkwrap to the geometry. Values can range from 0 to 1.0, where a value of 0 indicates shrinkwrap totally free from the geometry, and a value of 1.0 indicates shrinkwrap that is strictly on the geometry. The example in Figure 253: Surface Projection Factor illustrates the results of using different values for the Surface projection factor.

Figure 253: Surface Projection Factor

Surface Projection Factor = 0.2

Surface Projection Factor

Surface Projection Factor = 0.9

Surface Projection Factor