14.6.2. Limitations of the Wet Steam Model

The following restrictions and limitations currently apply to the wet steam model in Ansys Fluent:

  • Pressure inlet, mass-flow inlet, and pressure outlet are the only inflow and outflow boundary conditions available.

  • When the wet steam model is active, the access to the Create/Edit Materials dialog box is restricted. Therefore, if solid properties need to be set and adjusted, then it must be done in the Create/Edit Materials dialog box before activating the wet steam model.