This option will prevent a solver from executing, however all files required for
execution will be written to the run directory, including the script
.solvercmd
. This script must then be launched manually by you.
The graphical interface will show the execution log and update the convergence graphs
until the Stop → Kill button is
pressed.
This queue is useful when the .solvercmd
must be edited manually
before it is launched, or when the .solvercmd
script is executed on
a machine other than the computer where FENSAP-ICE is running.
On Windows, the .solvercmd
script must be launched as an argument
to nti_sh.exe (provided in $NTI_PATH).