Other Notes


Note:  Interactive query actions do not generate corresponding command language!


While doing queries and using the P key to pick a query location, other picking options that use the P key are disabled (such as Part, Cursor, Line, Plane, and LookAt Point).

Even though it is not shown in the dialogs above, the Time variable is also available. This time variable is the integration time for particle traces. Therefore, it is only defined and useful when probing particle traces. For other part types it will be undefined.


Important:  Min and Max Interactive Queries:

When performing an interactive query using the Min or Max options,

  • If a single part is selected, the Min (or Max) will return the Min (or Max) value on that single part.

  • If more than one part is selected, the Min (or Max) will return the Min (or Max) value for the entire model. When multiple parts are selected, EnSight will only return the value of the entire model, and not of the parts selected.