The models settings described in this section are set when creating a domain in CFX-Pre. For details, see Domains in the CFX-Pre User's Guide.
Because transport equations are not solved for species involved in the
flamelet library reactions, you should select either
Library
or Automatic
for all such
components.
Always set N2 to be a constraint. Components other than N2 and components covered by the flamelet library must be set to Automatic or Library.
Components not covered by the flamelet library should be set to
Transport Equation
. The transport equation components
must be minor components, as they are either postprocessed or their added mass
fractions will be subtracted from the mass fraction of the constraint material.
For details, see NO Model.