7.9.3. Kinetic Theory Models

When using solid particle collision models, the following pieces of advice may be useful:

  • Only run in transient mode with very small timesteps, typically 1E-4 [s].

  • Adaptive timestepping may help.

Details of the implementation of solid particle collision models are found in Solid Particle Collision Models in the CFX-Solver Theory Guide.