Specify the Heat Transfer as for an inlet boundary condition. This value is only used for the inflow portion of the opening. You can specify either:
Static Temperature
Opening Temperature
The opening temperature is similar to the
Total Temperature
, but the dynamic component is based only on the normal component of velocity.