11.7.2. The SPOS Data Record - Equilibrium Position

This data record may be used to optionally input the equilibrium position of the structure in the global fixed frame for the additional structure stiffness force calculation only. This data record does not move the structure to this position. Without this data record, the default position will be that position defined by Data Categories 1-2.

     2   5  7    11    16    21        31        41
    - --- -- ---- ----- ----- --------- --------- ------
   |X|   |  |SPOS|XXXXX|XXXXX|         |         |      ...
    - --- -- ---- ----- ----- --------- --------- ------
       |  |   |                   |         |         |
       |  |   |                   |----------------------
       |  |   |                   |
       |  |   |                   |
       |  |   |                   |_(2)-(7) 6 position coordinates (6E10.0)
       |  |   |                                         
       |  |   |_(1)Compulsory Data Record Keyword(A4)
       |  |
       |  |_Optional User Identifier(A2)
       |
       |_Compulsory END on last data record in data category(A3)

(2)-(7) The units for angular positions are degrees.