27.14. The PRMD Data Record - Print Mooring Drag

This data record causes the drag force on all tethers and dynamic mooring lines to be printed to the listing file, for cable dynamics analyses in Aqwa-Librium, Drift and Naut.

In Drift and Naut the frequency of printing is governed by the PREV data record.

In Librium the PBIS option is also required.

      2   5  7   11
    - --- -- ---- -----
   |X|   |  |PRMD|     |
    - --- -- ---- -----
       |  |   | 
       |  |   | 
       |  |   |
       |  |   |_Compulsory Data Record Keyword (A4)
       |  |
       |  |_Optional User Identifier (A2)
       |
       |_Compulsory END on last data record in Data Category (A3)